Computational Analysis of Triangular Perforated Fins in Staggered Arrangement
Author(s):
Abhijit G. Dhere , Govt. College of Engineering Amravati; Prof. Hemant S. Farkade, Govt. College of Engineering Amravati
Keywords:
Computational Analysis, Triangular Pin Fins, Force Convection, Staggered Arrangement
Abstract:
The present paper gives the computational analysis of the base plate equipped with triangular cross section fins in staggered manner. This analysis is done for 4 type of ratios, the inter fin spacing distance to side length of fin i.e (Sy/D) 1.208, 1.524, 1.944 and 3.417. in a duct having rectangular cross section area of 250mm x 100mm and a length of 1030 mm and 2 types of fins the solid triangular cross section fins and perforated fins. In the analysis air is forced to enter duct with 5m/s and carry away the heat in all types of arrangement for solid as well as perforated fins the analysis shows that the perforation in the fin has increased the heat transfer of the fin so perforation in the fins is suggested for higher thermal performance.
Other Details:
Manuscript Id | : | IJSTEV1I11068
|
Published in | : | Volume : 1, Issue : 11
|
Publication Date | : | 01/06/2015
|
Page(s) | : | 452-455
|
Download Article